BK-ZBW-3000KVA丨3 Phase Non-contact /Contactless Voltage Stabilizer
معلمات المنتج
- تنظيم مستقل ثلاثي المراحل
- High-Precision Voltage Stabilization
- High Efficiency & Energy Saving
- لا يوجد تشويه في شكل الموجة
- Ultra-Fast Response
- Safe & Reliable
الوصف
نظرة عامة على المنتج
The BK-ZBW Series Three-Phase Digital Non-contact /Contactless Voltage Stabilizer represents a new generation of rapid voltage stabilization equipment, developed through the advancement of compensating power voltage regulation devices.
It integrates core technologies including DSP chip control, rapid AC sampling, zero-crossing current switching, and fast compensation voltage regulation. This unit combines intelligent metering, rapid voltage stabilization, and fault diagnosis functions into one, ensuring safer, more efficient operation and enhanced voltage regulation precision.
Core components include an isolation transformer, thyristor voltage regulation module, MCU control core, high-precision current/voltage sampling elements, and safety protection devices. Employing a fully contactless control scheme—eliminating mechanical contact switching—it avoids traditional equipment’s contact wear issues while achieving surge-free operation, enhanced energy efficiency, and greater environmental sustainability. This represents an optimized integration of thyristor and transformer technologies.
This product is widely compatible with large electromechanical equipment in industrial, transportation, postal, defense, railway, and scientific research sectors. It provides reliable voltage stabilization for equipment demanding high precision and stability.
التطبيق
The BK-ZBW Series contactless voltage stabilizer is widely applied across multiple high-demand sectors, providing reliable voltage regulation for precision equipment and critical infrastructure:
التصنيع الصناعي
- CNC machine tools, automated production lines
- Industrial robots, welding equipment
- Textile machinery, precision machining tools
Data Centers & Communication Infrastructure
- Server rooms, cloud computing facilities
- 5G base stations, network switches
- Data transmission equipment, communication hubs
Medical & Laboratory Equipment
- MRI scanners, CT machines
- High-precision analytical instruments
- Clinical diagnostic equipment, laboratory testing devices
New Energy & Power Systems
- Solar/wind farm grid connection points
- Electric vehicle (EV) charging piles
- Substations, power distribution stations
- Renewable energy storage systems
المرافق التجارية والعامة
- Large shopping malls, office buildings
- Hospitals, airports, railway stations
- Rail transit systems, public utility facilities
المزايا التقنية
- تصميم بدون تلامس
يستخدم مكونات إلكترونية ذات حالة صلبة مثل التحكم في السيليكون بدلاً من الملامسات الميكانيكية لتنظيم الجهد. وهذا يجنبك مشكلات مثل تآكل التلامس الميكانيكي وضعف التلامس، مما يعزز الموثوقية ويقلل من تكاليف الصيانة ويطيل عمر الخدمة.
- التحكم الذكي والعرض الذكي
يستخدم نظام التحكم المركزي تحكمًا ذكيًا بمتحكم دقيق مع شاشة LCD. وهذا يوفر مراقبة في الوقت الحقيقي لمعلمات مثل الجهد والتيار والطاقة. تتيح الواجهة سهلة الاستخدام سهولة التشغيل.
- نطاق جهد الإدخال الواسع
يمكن أن يعمل في نطاق واسع من جهد الدخل وينظم الجهد بفعالية حتى مع التقلبات الكبيرة في الشبكة. وهذا يضمن استقرار الخرج.
- قابلية عالية للتخصيص والتوسع
قابل للتخصيص وفقاً لمتطلبات الجهد المحدد لمختلف التطبيقات الصناعية والتجارية. كما يمكن دمجها بسهولة في الأنظمة الكهربائية الحالية.
ميزات المنتج
- High-Precision Voltage Regulation
Utilizes thyristor technology for rapid and precise voltage adjustment, achieving regulation accuracy of ±1% or better to deliver stable voltage output to equipment.
- Ultra-Fast Response
Voltage response time ≤30ms enables swift adaptation to load changes and grid fluctuations, ensuring timely output stabilization and effective protection of electrical devices.
- Three-Phase Independent Leveling
Each phase voltage stabilizes independently without interference. When input voltage is unbalanced, it automatically balances three-phase output with a balance rate <1%, adapting to complex three-phase load scenarios.
- كفاءة عالية وتوفير في الطاقة
Operating efficiency reaches 99% or higher, consuming less energy than traditional voltage stabilizers and significantly reducing long-term equipment operating costs.
- Waveform Distortion-Free
Utilizes zero-crossing switching technology to eliminate current interruptions and surge currents during transitions, delivering pure sine wave voltage to loads for enhanced protection of precision equipment.
- Safe and Reliable Protection
Features multiple safeguards including overload, overvoltage, undervoltage, phase loss, short circuit, and overheat protection. Supports fault diagnosis and automatic bypass functionality to ensure stable operation even under abnormal conditions.
الملحقات الاختيارية
- واجهات الاتصال
RS232 و RS485 (اختياري)، RS485 (اختياري)، اتصال جاف (اختياري)، بطاقة شبكة (اختياري) لتلبية احتياجات المراقبة والإدارة المتنوعة.
- الوظائف الإضافية
تتوفر العديد من واجهات الاتصال والملحقات الاختيارية بناءً على متطلبات المستخدم، مما يعزز قابلية الجهاز للتطوير والتكيف.
المواصفات
| العنصر النموذجي | BK-ZBW-3000KVA | |
| Control Method | SCR electronic thyristor voltage regulation, three-phase independent voltage regulation technology | |
| المدخلات | الفولتية المقدرة | 3 × 380/400/414VAC (3L+N+G) |
| نطاق الجهد | Normal ±15%, (±20%,±30%,±40% optional) | |
| التردد | 50 هرتز/60 هرتز | |
| المخرجات | الفولتية المقدرة | 3 × 380/400/414VAC (3L+N+G) |
| Center Voltage | ±5℅ قابل للتعديل | |
| دقة تثبيت الجهد الكهربائي | ±1% ( ±1%~ ±5% Adjustable) | |
| معامل القدرة | ≥0.8(0.8~1 optional) | |
| وقت الاستجابة | ≤20MS | |
| Stabilization Time | ≤40MS/Step | |
| Filter Distortion | No additional waveform distortion (static state) | |
| Waveform Distortion | ≤1℅ | |
| الكفاءة | ≥98% | |
| الحماية | Overvoltage | he output phase voltage exceeds 5% (230V), and the interface displays an alarm. (It can be set according to actual requirements.) (Output cutoff is optional if needed.) |
| الجهد المنخفض | The output phase voltage is lower than 10% (195V), and the interface displays an alarm. (It can be set according to actual requirements.) (Output cutoff is optional if needed.) | |
| فقدان الطور | Equipped with interface alarm display. | |
| الحمل الزائد | Electronic detection, interface alarm activates 10 seconds after overload. (Output cutoff is optional if needed.) | |
| Overcurrent | Electronic detection, interface alarm activates 10 seconds after overload. (Output cutoff is optional if needed.) | |
| Overheat | Electronic detection, interface alarm activates 10 seconds after overload. (Output cutoff is optional if needed.) | |
| Short Circuit | Electronic detection, interface alarm activates 10 seconds after overload. | |
| الالتفافية | Uninterrupted automatic bypass | |
| Delayed Output | When mains power is turned on or restored after a blackout, output is delayed by 5 seconds (Optional) | |
| System Parameters | وضع العمل | يحتوي على وضعين للعمل: تنظيم الجهد التلقائي والتجاوز. |
| Voltage Adjustment Method | تنظيم ثلاثي الأطوار | |
| Three-phase Balance | توازن تلقائي للجهد ثلاثي الأطوار، زيادة ≤ 2% | |
| Working Pressure | No breakdown within 1 minute at 1500V | |
| Insulation Resistance | ≥5 MΩ | |
| Insulation Level | H Class | |
| Indicator | الفولتية | A, B, C, ∑ABC three phases have true effective value digital display. |
| الحالي | A, B, C, ∑ABC three phases have true effective value digital display. | |
| Working Status | Voltage stabilization state/mains power state. | |
| غير طبيعي | Overvoltage, undervoltage, overload, fuse blown. | |
| البيئة | درجة حرارة العمل | -10℃~50℃ |
| Humility | ≤95%,no condensation | |
| الارتفاع | ≤1500M for Nominal Power | |
| الضوضاء | ≤50db @ 1 meter | |
الأسئلة الشائعة
يرمز UPS إلى مزود الطاقة غير المنقطعة وهو جهاز يوفر إمداداً مستمراً بالطاقة لحماية الأحمال الحرجة من انقطاع الطاقة أو تذبذبها.
يتمثل الدور الرئيسي لوحدة إمداد الطاقة غير المنقطعة في توفير مصدر طاقة احتياطية لضمان استمرار عمل المعدات الحيوية عند انقطاع أو عدم استقرار طاقة المرافق، مما يجنب فقدان البيانات أو تلف المعدات.
تنقسم UPS بشكل أساسي إلى ثلاثة أنواع: غير متصل بالإنترنت، ومتصل بالإنترنت، وتفاعلي عبر الإنترنت.
عند اختيار سعة الطاقة الخاصة بـ UPS، تحتاج إلى النظر في إجمالي الطلب على الطاقة للحمل، ويوصى عادةً باختيار طاقة أكبر قليلاً من إجمالي طاقة الحمل لـ UPS لضمان وقت استعداد كافٍ.
يعتمد زمن الاستعداد لوحدة إمداد الطاقة غير المنقطعة على سعة البطارية وطاقة الحمل. يتراوح وقت الاستعداد عادةً من 10 دقائق إلى عدة ساعات، ويمكن تحديد الاحتياجات المحددة وفقًا لسيناريو التطبيق الفعلي.