Line-Frequency UPS | BK-GH33-30KVA Transformer-Based Double Conversion UPS
معلمات المنتج
- Advanced Line-Frequency Design
- قدرة قوية على التكيف البيئي
- Exceptional Overload Capacity
- الحماية الشاملة
- إدارة البطارية المتقدمة
الوصف
نظرة عامة على المنتج

The BK-GH33 Series 30KVA Industrial grade UPS is a high-performance line-frequency UPS (also known as low-frequency UPS) featuring three-phase input and three-phase output, specifically engineered for mission-critical applications requiring uncompromising stability and reliability. As a premium transformer-based online UPS و double conversion line frequency UPS, it integrates a heavy-duty industrial-grade isolation transformer, delivering inherent galvanic isolation that effectively shields sensitive equipment from grid harmonics, electromagnetic interference (EMI), voltage spikes, and ground loops.
Unlike transformerless online UPS alternatives, this UPS with built-in isolation transformer adopts true Double Conversion UPS technology, ensuring 0ms seamless transfer between mains and battery modes to eliminate downtime risks for critical loads. Equipped with a high-precision step-down transformer for voltage stabilization, it maintains exceptional output voltage regulation even amid extreme grid fluctuations, while its low total harmonic distortion input (THDi) qualifies it as a Low THDi line-frequency UPS that complies with global green energy standards.
The BK-GH33-30KVA offers enhanced load-carrying capacity, making it a superior UPS for inductive loads and motor startup—a key advantage over standard models. Its rugged design and High surge withstand capability UPS performance ensure reliable operation in extreme temperatures, high dust, and volatile power conditions, solidifying its reputation as a Robust UPS for harsh industrial environments.
التطبيقات
Industrial Automation & Control
As a dedicated Industrial grade UPS, it protects PLCs, automated production lines, CNC machines, and industrial robots—its High surge withstand capability UPS design handles the inrush currents of inductive loads and motor startup, while galvanic isolation suppresses EMI to avoid costly production downtime in harsh factory settings.
Data Centers & IT Infrastructure
This double conversion line frequency UPS ensures 24/7 power for core servers, storage arrays, and network switches—0ms transfer time prevents data loss, while the built-in isolation transformer delivers pure power that optimizes IT equipment lifespan and reduces maintenance costs, supporting data center PUE optimization goals.
Medical & Healthcare Facilities
Compliant with medical-grade power standards, the line-frequency UPS provides stable power for diagnostic scanners, laboratory instruments, and operating room life support systems—its low leakage current, precise voltage regulation, and galvanic isolation eliminate risks of equipment malfunctions that could compromise patient safety.
Oil & Gas & Energy Sector
Ideal for offshore platforms, substation automation, and renewable energy systems, this Robust UPS for harsh industrial environments withstands extreme temperatures, humidity, and voltage instability—its low-frequency UPS architecture ensures reliable performance in remote, high-stress energy infrastructure.
Manufacturing & Heavy Industry
Supports heavy machinery, assembly lines, and precision tooling—its ability to handle mixed inductive/capacitive loads and step-down transformer for voltage stabilization make it the preferred UPS نظام for manufacturing facilities where power quality directly impacts product quality and production efficiency.
ميزات المنتج
Industrial-Grade Line-Frequency Transformer Design
As a authentic transformer-based online UPS و low-frequency UPS, it integrates a heavy-duty isolation transformer that provides physical galvanic isolation, suppressing grid interference and voltage spikes—essential for harsh industrial environments and sensitive equipment protection.
True Double Conversion Technology
Operates as a pure Double Conversion UPS with 0ms transfer time between mains and battery modes—the inverter powers the load 24/7, ensuring uninterrupted power that outperforms traditional standby UPS systems and even some High-frequency double-conversion UPS models in critical scenarios.
قدرة فائقة على التكيف مع الأحمال
Engineered as a specialized UPS for inductive loads and motor startup, it handles inrush currents and mixed load types (inductive, capacitive, resistive) with ease.
Precise Voltage Stabilization
Equipped with a step-down transformer for voltage stabilization, it maintains output voltage regulation of ±1% even when input voltage fluctuates widely—eliminating the need for additional voltage regulators and ensuring consistent performance for precision equipment.
Comprehensive Protection Mechanisms
Integrates over-voltage, under-voltage, overload, short-circuit, over-temperature, and battery over-charge/discharge protection—its rugged design safeguards both the UPS نظام and connected equipment, minimizing repair costs and downtime.
Smart Monitoring & Remote Management
Features an intuitive LCD display for real-time status tracking (input/output parameters, battery health, faults) — standard RS232/USB interfaces and optional SNMP card enable remote network management, aligning with modern industrial AIoT integration trends.
المواصفات
| الطراز | BK-GH33-30KVA | |
| الطاقة الاستيعابية | 30 كيلو فولت أمبير/24 كيلو وات | |
| المرحلة | 3-phase in/3-phase out | |
| التكنولوجيا | Online Double Conversion; Harmonic suppression; SPWM pulse width modulation inverter; Electromagnetic isolation; IGBT inversion technology | |
| المدخلات | الجهد الاسمي | 380/400/415 فولت تيار متردد 380/400/415 فولت تيار متردد |
| نطاق الجهد | ± 25% | |
| تحمل التردد | 46Hz ~ 54Hz @ 50Hz, 56Hz ~ 64Hz @ 60Hz | |
| معامل القدرة | >0.95 (إضافة فلتر) | |
| المخرجات | الجهد الاسمي | 380/400/415 فولت تيار متردد 380/400/415 فولت تيار متردد |
| تنظيم الجهد | ± 1% | |
| معامل القدرة | 0.8 (standard), 0.9 (optional) | |
| التردد | 50/60Hz±1% | |
| شكل الموجة | موجات صوتية نقية | |
| THD | ≤2% (Pure linear load);≤4%(Non-linear load) | |
| وقت التحويل | 0 مللي ثانية | |
| Current Crest Ratio | 3 :1 | |
| الالتفافية | Connection Type | Hardwire 4 wire (3Ph+N) |
| الجهد الاسمي | 380/400/415 فولت تيار متردد 380/400/415 فولت تيار متردد | |
| نطاق الجهد | 304Vac~456Vac | |
| سعة التحميل الزائد | 150 ~ 180%:1h ~ 30s;180% ~ 200%:30s ~ 200ms | |
| Battery&Charge | نوع البطارية | Lead-acid battery |
| جهد البطارية | 384 Vac (base on 32pcs batteries) | |
| تيار الشحن | 1~40A | |
| الكفاءة | وضع الخط | 89% |
| وضع البطارية | 90% | |
| وظيفة الإنذار | نطاق الإنذار | التحميل الزائد للإخراج، خلل في طاقة التيار المتردد، عطل في UPS، انخفاض جهد البطارية |
| طريقة الإنذار | إنذار صوتي | |
| وظيفة الحماية | Output overload, short circuit, over-temperature, battery undervoltage, output over/undervoltage, fan failure alarm. | |
| الاتصالات والإدارة | الواجهة | Standard configuration:RS232 Optional configuration:RS485/SNMP/Dry Contact |
| لوحة العرض | شاشة LCD/مؤشر حالة LED | |
| البيئة | درجة حرارة التشغيل | 0~55℃ |
| الرطوبة | 0 ~ 95% (دون تكاثف) | |
| الارتفاع | ≤1500m no derate, >1500m, derating 1% 100m | |
| مستوى الضوضاء | <65dB@ 1 meter | |
| المعايير | السلامة/التوافق الكهرومغناطيسي/الأداء | IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3, IEC/EN 61000-6-2, IEC/EN 61000-6-4 |
| Certifications | CE/ROHS | |
| التصنيع | الأيزو | |
| البدنية | IP Protection | IP20 |
| الأبعاد (العرض×العمق×الارتفاع) | 960*560*1333mm | |
| الوزن | 257kg | |
Kindly note: The technical parameters provided here are for reference only and are intended as a selection guide. Given that the product offers various customization options, such as power rating, voltage configuration, battery solutions, and special certifications, the final product specifications will be subject to the final order document.
الأسئلة الشائعة
يرمز UPS إلى مزود الطاقة غير المنقطعة وهو جهاز يوفر إمداداً مستمراً بالطاقة لحماية الأحمال الحرجة من انقطاع الطاقة أو تذبذبها.
يتمثل الدور الرئيسي لوحدة إمداد الطاقة غير المنقطعة في توفير مصدر طاقة احتياطية لضمان استمرار عمل المعدات الحيوية عند انقطاع أو عدم استقرار طاقة المرافق، مما يجنب فقدان البيانات أو تلف المعدات.
تنقسم UPS بشكل أساسي إلى ثلاثة أنواع: غير متصل بالإنترنت، ومتصل بالإنترنت، وتفاعلي عبر الإنترنت.
عند اختيار سعة الطاقة الخاصة بـ UPS، تحتاج إلى النظر في إجمالي الطلب على الطاقة للحمل، ويوصى عادةً باختيار طاقة أكبر قليلاً من إجمالي طاقة الحمل لـ UPS لضمان وقت استعداد كافٍ.
يعتمد زمن الاستعداد لوحدة إمداد الطاقة غير المنقطعة على سعة البطارية وطاقة الحمل. يتراوح وقت الاستعداد عادةً من 10 دقائق إلى عدة ساعات، ويمكن تحديد الاحتياجات المحددة وفقًا لسيناريو التطبيق الفعلي.