BK-L33-10KVA(PF0.8)丨Three Phase High-Frequency Online UPS
PRODUKTPARAMETER
- True Online Double-Conversion Technology
- Advanced High-Frequency Transformerless Design
- Ultra-Wide Input Voltage & Frequency Range
- Hohe Effizienz und Energieeinsparung
- Full Digital DSP Control
Beschreibung
Produktübersicht
The BK-L33 Series is a cutting-edge High-frequency online UPS featuring a transformer-less, high-frequency design—redefining efficiency and reliability as a premium Online double-conversion UPS. By eliminating bulky line-frequency transformers, this Transformerless online UPS reduces weight by up to 40%, slashes power losses, and lowers total cost of ownership (TCO) for global enterprises.
As a true High-frequency double-conversion UPS, it adopts online double-conversion technology, ensuring 24/7 inverter-powered load supply with 0ms transfer time. This seamless protection shields critical equipment from voltage sags, surges, and full blackouts—essential for mission-critical IT and industrial applications worldwide. Equipped with an intelligent active-PFC rectifier, the Double-conversion UPS boasts an ultra-wide input voltage range, maintains input Leistungsfaktor ≥0.99, and keeps THDi <5%, easing strain on upstream infrastructure and meeting global green-energy norms (IEC/EN 62040-2 Category C3).
Fusing DSP-controlled SPWM precision, compact footprint, and enterprise-grade reliability, this USV-Anlage sets a new standard for green, efficient power protection—ideal as a UPS for data center, UPS for server room, UPS for medical equipmentund UPS system for enterprise across North America, Europe, and Southeast Asia.
Anwendungen
Finanzen
Ensures uninterrupted power for ATMs, trading terminals, and core banking systems. As a trusted UPS System for enterprise, it safeguards transaction integrity and data security during outages—critical for global financial institutions.
Telekommunikation
Provides reliable backup for base stations, switching centers, and fiber network equipment. This Double-conversion UPS maintains 24/7 connectivity, preventing service disruption for telecom operators worldwide.
Regierung
Supports mission-critical operations in command centers, e-governance platforms, and secure facilities. The High-frequency online UPS delivers high-availability power protection for sensitive government infrastructure.
Transport
Powers traffic control systems, railway signaling, and airport navigation. The Online double-conversion UPS ensures zero downtime for intelligent transport infrastructure across international markets.
Herstellung
Protects PLCs, industrial PCs, and automated production lines from voltage fluctuations. This UPS System avoids costly downtime and equipment damage for global manufacturing plants.
Education
Secures campus networks, computer labs, and smart classroom systems. The High-frequency double-conversion UPS ensures continuity of digital learning for overseas universities and schools.
Data Centers & Server Rooms
Delivers clean, stable power to servers, storage, and networking gear. As a dedicated UPS for data center and UPS for server room, it meets Tier III/IV reliability standards with high efficiency and scalability—perfect for hyperscale and colocation facilities.
Precision Equipment Rooms
Supplies ultra-stable, low-distortion power to medical imaging devices, lab instruments, and semiconductor testing equipment. This UPS for medical equipment meets strict electrical quality requirements for healthcare and research institutions globally.
Produktmerkmale
Advanced Transformerless High-Frequency Online UPS Architecture
Eliminates bulky power frequency transformers, reducing overall weight by ~40% while boosting power density. This Transformerless online UPS cuts energy consumption and cooling requirements—aligning with overseas enterprises’ sustainability goals.
True Online Double-Conversion UPS Operation
Whether mains power is normal or abnormal, the inverter continuously powers the load with 0ms switching time. This Double-conversion UPS ensures uninterrupted, stable operation for critical equipment in global mission-critical environments.
Built-in Intelligent Active PFC for High-Frequency UPS
Supports an ultra-wide input voltage range, easily handling voltage sags/dips. It actively improves input power factor to ≥0.99 and limits THDi <5%, meeting international green energy and power quality standards.
Emergency Power Off (EPO) for Enterprise UPS System
One-button safe shutdown during fires, floods, or maintenance—protecting personnel and equipment in compliance with global safety regulations for commercial and industrial facilities.
DSP Full-Digital Control for Double-Conversion UPS
A high-performance DSP achieves all-digital control of PFC, inverter, and charger, delivering sub-millisecond response and higher precision. This enhances the reliability of the UPS System for sensitive overseas applications.
High Output Power Factor for Versatile Loads
Supports modern high-power IT, medical, and industrial loads without derating. This flexibility makes it a top choice as a UPS for data center, UPS for medical equipment, and UPS system for enterprise with diverse load requirements.
Spezifikationen
| Modell | BK-L33-10KVA(PF0.8) | |
| Kapazität | 10KVA/8KW | |
| Eingabe | Verkabelung | Three-phase four wires + Ground |
| Nennspannung | 380/400/415Vac | |
| Spannungsbereich | 208-304Vac (50% load); 304-478Vac (100% load) | |
| Frequenzbereich | 46Hz-54Hz (@50Hz system); 56Hz-64Hz (@60Hz system) | |
| Input Power Factor | ≥0.99 (100% load) | |
| Ausgabe | Verkabelung | Three-phase four wires + Ground |
| Nennspannung | 380/400/415Vac | |
| Spannungsregelung | ±1% | |
| Frequency Range (Synchronous Range) | 46Hz-54Hz (@50Hz system); 56Hz-64Hz (@60Hz system) | |
| Frequency Range (Battery Mode) | 50Hz±0.1Hz or 60Hz±0.1Hz | |
| Output Power Factor | 0.8 | |
| Verzerrung (THDV%) | ≤2% (@100% linear load); ≤5% (@100% non-linear load) | |
| Overload Capability (AC Mode) | 100%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 1 second | |
| Overload Capability (Battery Mode) | 100%-110%: 30 seconds; 110%-130%: 10 seconds; >130%: 1 second | |
| Stromspitzenwert-Verhältnis | 3:1 (maximum) | |
| Umschaltzeit | 0ms | |
| Batterie | Akku-Typ | Externe Batterie |
| Modell | 12V | |
| Number of Batteries | 16/18/20 units (optional) | |
| Ladestrom | 4A | |
| Ladespannung | N×13.65VDC±1% (N=number of batteries) | |
| Wirkungsgrad | Linien-Modus | 89% |
| ECO-Modus | 86% | |
| Verwaltung | Anzeigefeld | LCD-Display / LED-Statusanzeige |
| Kommunikation Funktion | Intelligent RS-232 or USB, supporting Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, MAC | |
| Wahlweise SNMP | Supports power management via SNMP manager and web browser | |
| Umwelt | Betriebstemperatur | 0~40℃ (Battery life will be reduced when temperature >25℃) |
| Luftfeuchtigkeit | <95% RH (non-condensing) | |
| Höhenlage | <1000m for Nominal power | |
| Lärmpegel | <60dB@1meter | |
| Normen | Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 Category C3 | |
| Physisch | IP-Klasse | IP20 |
| Dimensions (D×W×H) | 575×250×550 mm | |
| Gewicht | 33.5 kg | |
FAQs
UPS steht für Uninterruptible Power Supply (unterbrechungsfreie Stromversorgung) und ist ein Gerät, das eine kontinuierliche Stromversorgung bietet, um kritische Verbraucher vor Stromausfällen oder -schwankungen zu schützen.
Die Hauptaufgabe einer USV besteht darin, eine Ersatzstromquelle bereitzustellen, um sicherzustellen, dass kritische Geräte auch bei einer Unterbrechung oder Instabilität der Stromversorgung weiter betrieben werden können, um Datenverlust oder Geräteschäden zu vermeiden.
Der USV wird hauptsächlich in drei Arten unterteilt: offline, online und online interaktiv.
Bei der Wahl der Leistungskapazität der USV müssen Sie den Gesamtstrombedarf der Last berücksichtigen. Es wird in der Regel empfohlen, eine etwas größere Leistung als die Gesamtlast der USV zu wählen, um eine ausreichende Standby-Zeit zu gewährleisten.
Die Standby-Zeit einer USV hängt von der Batteriekapazität und der Lastleistung ab. Die Standby-Zeit reicht in der Regel von 10 Minuten bis zu mehreren Stunden, wobei die spezifischen Anforderungen je nach Anwendungsszenario festgelegt werden können.
.png)
.png)
-main.jpg)
-sub-1.jpg)
-sub-2.jpg)
-sub-3.png)
-sub-3.jpg)
-sub-4.jpg)
-sub-5.jpg)
-main-150x150.jpg)
-sub-1-150x150.jpg)
-sub-2-150x150.jpg)
-sub-3-150x150.png)
-sub-3-150x150.jpg)
-sub-4-150x150.jpg)
-sub-5-150x150.jpg)
-main-768x768.jpg)



-main-768x768.jpg)