Bienvenue chez BKPOWER !

BK-L31-15KVA丨3 Phase in/1 Phase out High-Frequency Online UPS
PARAMÈTRES DU PRODUIT
- True Online Double-Conversion Technology
- Advanced High-Frequency Transformerless Design
- Ultra-Wide Input Voltage & Frequency Range
- Haute efficacité et économies d'énergie
- Full Digital DSP Control
Description
Aperçu du produit
The BK-L31 Series is a high-performance Double Conversion UPS engineered for medium-to-large sensitive loads, featuring three-phase input and single-phase output. As a premium High-frequency double-conversion UPS, it adopts true online double-conversion architecture, enabling 0ms seamless transfer between mains and battery modes—completely isolating critical loads from grid fluctuations, harmonics, surges, and outages.
This online UPS supports customizable external battery configurations to meet extended backup time requirements, paired with a wide input voltage range and high input power facto. As a Transformerless online UPS (high-frequency design), it delivers a stable pure sine wave output with low harmonic distortion, making it an ideal Uninterruptible Power Supply for industrial control systems, data centers, medical equipment, and other mission-critical scenarios globally.
Applications
This versatile UPS en ligne caters to diverse high-reliability scenarios, leveraging its three-phase input flexibility and external battery advantage:
Industrial Control Systems
Protects PLCs, automated production lines, CNC machines, and industrial robots. This Double Conversion UPS withstands grid instability and suppresses electromagnetic interference, avoiding costly production downtime.
Data Centers & IT Rooms
Powers servers, storage arrays, and network switches. The 0ms transfer time of this High-frequency double-conversion UPS prevents data loss, while low harmonic distortion ensures compatibility with precision IT equipment.
Équipement médical
Supports high-power medical devices (e.g., diagnostic scanners, laboratory instruments). This Alimentation sans interruption delivers stable output voltage and low leakage current, meeting medical-grade power quality requirements.
Commercial Infrastructure
Covers financial server rooms, communication base stations, and smart building control systems. The wide input range of this Système UPS adapts to complex urban grid environments.
Energy & Transportation
Powers new energy station monitoring systems, substation automation equipment, and rail transit signal systems.
Caractéristiques du produit
Three-Phase Input/Single-Phase Output Design
Adapted to medium-to-large three-phase power systems worldwide, while supporting single-phase sensitive loads—ideal for industrial and commercial scenarios where three-phase grid access is available but loads require single-phase power.
True Double Conversion UPS Architecture
0ms transfer time between mains and battery modes; the inverter powers the load continuously, eliminating downtime risks for critical equipment— a core advantage of Double Conversion UPS.
High-Frequency Online UPS Design
Leverages a transformer-less high-frequency topology, enhancing power density and reducing energy loss—aligning with global energy-saving trends and lowering operational costs.
Wide Input Voltage Adaptability
Handles grid sags and surges without frequent battery activation, adapting to unstable grid conditions across regions.
Comprehensive Overload Protection
Multi-stage overload handling in AC and battery modes safeguards the Système UPS and connected devices from damage, complying with international safety standards.
Spécifications
| Modèle | BK-L31-15KVA | |
| Capacité | 15KVA/12KW | |
| Phase | Three-phase input, single-phase output | |
| Entrée | Tension nominale | 380/400/415VAC |
| Plage de tension | 208-478VAC (three-phase, 50% load); 304-478VAC (100% load) | |
| Gamme de fréquences | 46-54Hz (@50Hz system); 56-64Hz (@60Hz system) | |
| Entrée Facteur de puissance | ≥0.99 (100% load) | |
| Sortie | Tension nominale | 380/400/415VAC ±1% |
| Gamme de fréquences | Mains mode: Synchronized with input; Battery mode: 50/60Hz ±0.1Hz | |
| Forme d'onde | Onde sinusoïdale pure | |
| THD | ≤3% (@100% linear load); ≤8% (@100% non-linear load) | |
| Overload Capability | AC Mode: 100%-110%: 60min; 110%-130%: 30min; >130%: 1min | |
| Battery Mode: 100%-110%: 60min; 110%-130%: 30min; >130%: Immediate shutdown | ||
| Temps de transfert | Mains ↔ Battery: 0ms; Inverter ↔ Bypass: ≤4ms | |
| Current Crest Ratio | 3:1 | |
| Batterie | Type de batterie | External Battery |
| Tension de la batterie | Customizable to 240VDC | |
| Battery Count | Customizable to 20 units | |
| Courant de charge | 4A~6A | |
| Efficacité | Mode CA | 91% |
| Mode batterie | 91% | |
| Indicators | LCD | Load Level,Battery Level,AC Mode,Battery Mode,Bypass Mode,and Fault Indicator Via LCD |
| Environnement | Température de fonctionnement | 0~40℃ |
| Humidité | <95% RH (non-condensing) | |
| Niveau de bruit | ≤58dB@1meter | |
| Communication & Monitoring | RS232 (485 optional); Smart slot (SNMP optional); SMS alert (optional) | |
| Dimensions (L×P×H) | 465×190×323mm | |
| Poids | 15.3kg | |
Kindly note: The technical parameters provided here are for reference only and are intended as a selection guide. Given that the product offers various customization options, such as power rating, voltage configuration, battery solutions, and special certifications, the final product specifications will be subject to the final order document.
FAQ
UPS signifie Uninterruptible Power Supply (alimentation sans interruption) et est un dispositif qui fournit une alimentation continue pour protéger les charges critiques contre les pannes ou les fluctuations de courant.
Le rôle principal d'une ASI est de fournir une source d'alimentation de secours afin que les équipements critiques puissent continuer à fonctionner lorsque l'alimentation électrique est interrompue ou instable, évitant ainsi la perte de données ou l'endommagement de l'équipement.
L'UPS se divise principalement en trois types : hors ligne, en ligne et interactif en ligne.
Lors du choix de la puissance de l'onduleur, vous devez tenir compte de la demande totale de puissance de la charge. Il est généralement recommandé de choisir une puissance légèrement supérieure à la puissance totale de la charge de l'onduleur afin de garantir un temps de veille suffisant.
Le temps de veille d'une ASI dépend de la capacité de la batterie et de la puissance de la charge. Le temps de veille varie généralement de 10 minutes à plusieurs heures, et les besoins spécifiques peuvent être déterminés en fonction du scénario d'application réel.
.png)
.png)
-external-main.jpg)
-sub-1.jpg)
-sub-3.png)
-sub-2.jpg)
-sub-3.jpg)
-sub-5.jpg)
-sub-4.jpg)
-external-main-150x150.jpg)
-sub-1-150x150.jpg)
-sub-3-150x150.png)
-sub-2-150x150.jpg)
-sub-3-150x150.jpg)
-sub-5-150x150.jpg)
-sub-4-150x150.jpg)


-768x768.jpg)


-external-main-768x768.jpg)