BK-RM50-500KVA丨Three-Phase Modular UPS丨Online Double-Conversion UPS
PARAMÈTRES DU PRODUIT
- N+X Parallel Redundancy Modular UPS
- Hot-Swappable Power Module UPS
- Full Digital Control Critical Power Supply
- Intelligent Battery Management Modular UPS
- High-Efficiency Energy-Saving Modular UPS
Description
Aperçu du produit
The BK-RM Series is a high-performance modular UPS (Uninterruptible Power Supply) featuring 3-phase three-wire design, advanced modular architecture, and N+X parallel redundancy technology. As a core 3 phase modular UPS solution, its capacity ranges from 300KVA to 600KVA, enabling global users to flexibly configure capacity based on actual needs and adopt phased investment strategies—ideal for cost optimization in growing businesses.
This N+X redundant modular UPS fully addresses common global power supply issues, including power outages, overvoltage, undervoltage, voltage fluctuations, frequency drift, surges, spikes, dips, waveform distortion, and harmonic interference. It delivers stable and reliable critical power protection for mission-critical equipment, complying with global grid standards (380/400/415VAC) to meet the power requirements of diverse regions worldwide.

Application Areas
This modular UPS system is tailored for scenarios demanding high-reliability power supply across global industries:
Key Infrastructure
- Data centers (cloud computing, colocation facilities)
- Traffic dispatching systems (smart city transportation networks)
- Security monitoring systems (critical infrastructure surveillance)
Industrial Fields
- Industrial automation equipment (smart manufacturing lines)
- Production line critical power supply (precision machining processes)
- Manufacturing process control systems (chemical & electronics production)
Commercial & Financial Sectors
- Corporate data rooms (global enterprise IT infrastructure)
- Financial institution core equipment (banking & stock transaction systems)
- Commercial office building critical loads (HVAC & emergency systems)
- Transaction processing centers (global e-commerce & payment platforms)
Caractéristiques du produit
Full Digital Control for Modular UPS
All components of this modular UPS adopt full digital control technology, achieving superior performance indicators and a stable, reliable control system. It accurately responds to global grid variations, ensuring consistent power output for critical loads.
High Power Density & Hot-Swappable UPS Modules
The 50KVA hot-swappable UPS modules support online hot-swapping, allowing users to add or remove modules without shutting down the system. The rack-mountable design saves data center floor space and reduces wiring complexity—aligning with global data center efficiency standards.
Independent Air Duct Design for Modular UPS
Configurable charging current and automatic smooth switching between charging modes (constant current, constant voltage, floating charge) adapt to 10-50 battery cells. This extends battery lifespan and supports global battery standards, reducing maintenance costs for international users.
LCD Display & Multi-Language Support (Global Use)
Equipped with a touch LCD screen supporting Chinese and English—critical for global teams. LED indicators provide intuitive operational status, facilitating on-site monitoring and parameter setting for international technicians.
Emergency Shutdown (EPO) for Global Safety Compliance
The integrated emergency shutdown button quickly cuts off UPS output in emergencies, complying with global safety standards (IEC/EN 62040-1) to protect personnel and equipment worldwide.
Spécifications
| Modèle | BK-RM50-500KVA | |
| Basic Information | Phase | 3 Phase In / 3 Phase Out |
| Cabinet Capacity | 500KVA/500KW | |
| Capacité du module d'alimentation | 50KVA/50KW | |
| Max Power Modules | 10 | |
| Entrée principale | Tension nominale | 380/400/415VAC(3Ph+N+G) |
| Plage de tension | 138~485Vac (no derating above 305Vac) | |
| Gamme de fréquences | 40~70Hz | |
| Facteur de puissance | ≥0.99 | |
| THDi | ≤3% (100% linear load) | |
| Entrée de dérivation | Tension | 380/400/415VAC |
| Voltage Upper Limit | +25% (optional: +10%, +15%, +20%) | |
| Voltage Lower Limit | -45% (optional: -10%, -20%, -30%) | |
| Frequency Tracking Range | ±10% Hz | |
| Power Walk In Function | Supported | |
| Compatibilité des générateurs | Supported | |
| Sortie | Tension nominale | 380/400/415VAC(3Ph+N+G) |
| Voltage Accuracy | ±1% | |
| Frequency (Mains Mode) | Synchronized with input; adjustable tracking range (±1%, ±2%, ±4%, ±5%) | |
| Frequency (Battery Mode) | 50/60±0.1Hz | |
| Load Peak Ratio | 3:1 | |
| Temps de transfert | 0ms | |
| Capacité de surcharge | ≤110%: 60min; ≤125%: 10min; ≤150%: 1min; >150%: switch to bypass immediately | |
| THDV | ≤2% (100% linear load); ≤3% (100% non-linear load) | |
| Efficacité | ≥96% | |
| Communication Interface | RS232, RS485, 2 Intelligent Slots, Dry Contacts, CAN | |
| Battery/Charger | Plage de tension | ±180VDC~±300VDC (30~50 cells optional) |
| Power Module Charging Current | 20A max | |
| Environnement | Température de fonctionnement | 0℃~40℃ |
| Température de stockage | -25℃~55℃ | |
| Humidité relative | 0~95% (non-condensing) | |
| Altitude | <1500m (derating required above 1500m) | |
| Noise Level (1m distance) | <70dB | |
| Normes | Safety | IEC 62040-1:2017 / EN 62040-1 |
| EMC | IEC 62040-2:2018 / EN 62040-2 | |
| Performance and Test Methods | IEC 62040-3:2021 / EN 62040-3 | |
Model Comparison Chart
| Modèle | Dimensions (D×W×H) | Poids | ||
| Cabinet | Power Module | Cabinet | Power Module | |
| BK-RM-300KVA | 850×600×2000mm | 625×440×130 mm | 280 Kg | 32 Kg |
| BK-RM-400 KVA | 850×1200×2000 mm | 625×440×130 mm | 600 Kg | 32 Kg |
| BK-RM-500 KVA | 850×1200×2000 mm | 625×440×130 mm | 650 Kg | 32 Kg |
| BK-RM-600 KVA | 850×1200×2000 mm | 625×440×130 mm | 720 Kg | 32 Kg |
FAQ
UPS signifie Uninterruptible Power Supply (alimentation sans interruption) et est un dispositif qui fournit une alimentation continue pour protéger les charges critiques contre les pannes ou les fluctuations de courant.
Le rôle principal d'une ASI est de fournir une source d'alimentation de secours afin que les équipements critiques puissent continuer à fonctionner lorsque l'alimentation électrique est interrompue ou instable, évitant ainsi la perte de données ou l'endommagement de l'équipement.
L'UPS se divise principalement en trois types : hors ligne, en ligne et interactif en ligne.
Lors du choix de la puissance de l'onduleur, vous devez tenir compte de la demande totale de puissance de la charge. Il est généralement recommandé de choisir une puissance légèrement supérieure à la puissance totale de la charge de l'onduleur afin de garantir un temps de veille suffisant.
Le temps de veille d'une ASI dépend de la capacité de la batterie et de la puissance de la charge. Le temps de veille varie généralement de 10 minutes à plusieurs heures, et les besoins spécifiques peuvent être déterminés en fonction du scénario d'application réel.