Welcome to BKPOWER!

Single-Phase Line-Interactive UPS (3000VA/2400W)丨BK-L11-3KVA
PRODUCT PARAMETERS
- Ultra-Clean Pure Sine Wave Output
- Ultra-Wide Input Voltage Adaptability
- High-Speed 4ms Power Transfer
- Intelligent Energy-Saving Charging
- Comprehensive Multi-Level Protection
Description
Product Overview
The BK-L11-3KVA Line-Interactive UPS (Pure Sine Wave) is a high-capacity UPS System and professional power supply, engineered for home UPS (UPS for home), Small-office UPS, IT infrastructure, precision instruments, and medium-power protection scenarios. As the flagship model of the 1000VA-3000VA series, this Line-Interactive UPS integrates advanced automatic voltage regulation (AVR) technology, a wide input voltage range, and flexible battery expansion, tailored for compact installation in home, small office, and professional environments. It delivers stable, high-performance UPS power for high-power key electronic devices, precision equipment, and heavy-duty daily-use appliances—becoming the preferred choice for users seeking robust power backup, voltage stabilization, and efficient energy management.
Applications
This Line-Interactive UPS (professional power supply) is a versatile UPS System, widely applied in home, small office, and professional scenarios to provide targeted, reliable UPS power protection:
UPS for Home & Residential High-Power Use
Perfect for high-power home equipment such as large-screen televisions, multi-device desktop setups, external storage servers, and home security monitoring systems. As a high-capacity home UPS, it ensures uninterrupted use of power-hungry devices, preventing data loss and equipment damage from power outages or voltage fluctuations.
Small-office UPS & Medium-Power Office Applications
Ideal for small office IT infrastructure including high-performance workstations, network servers, storage arrays, printers, and multi-device office setups. This Small-office UPS maintains seamless business operations by stabilizing unstable mains power, providing extended emergency backup, and safeguarding critical business data and equipment.
Professional & Precision Medium-Power Equipment
Suitable for medical devices (high-precision monitors, diagnostic equipment), laboratory analytical instruments, audio-visual production gear, and small-scale industrial control devices. The pure sine wave UPS power meets the high-power and high-stability requirements of sensitive professional equipment, ensuring accurate and continuous operation.
Product Features
As a high-performance Line-Interactive UPS and professional power supply, this UPS System combines the advantages of home UPS, Small-office UPS, and medium-power UPS power solutions with the following core features:
Wide Input Voltage Range
Adapts to harsh mains voltage fluctuations, reducing battery switching frequency to extend service life—ideal for unstable power environments in home, small office, and professional high-power scenarios.
Pure Sine Wave UPS Power Output
Delivers high-quality pure sine wave output with THD <3% (linear load) and <6% (non-linear load), fully matching the power requirements of high-power high-precision devices and sensitive electronics in home, small office, and professional applications.
Advanced AVR for Stable Power Supply
Automatic Voltage Regulation (AVR) technology dynamically adjusts input voltage deviations, balancing efficiency and protection to ensure consistent 220VAC output— a key advantage for home UPS and Small-office UPS users needing reliable voltage stabilization for high-power devices.
Intelligent Charging & Extended UPS Power Backup
Supports fast charging (recovers to 90% capacity in 4 hours for built-in batteries) and adjustable charging current (1A/2A/4A/6A for external batteries), maximizing battery life and flexible long-duration backup time for both UPS for home and Small-office UPS high-power needs.
4ms Fast Transfer Time
Instantly switches between mains and battery modes under standard conditions, avoiding data corruption and equipment failure—critical for protecting valuable data and sensitive high-power devices in all application scenarios.
Specifications
| Model item | BK-L11-3KVA | |
| Capacity | 3000VA/2400W | |
| Topology | Online interactive | |
| Efficiency | AC Mode | ≥85% |
| Battery Mode | ≥83% | |
| Input | Rated Voltage | 220VAC |
| Voltage Range | 145Vac-275Vac | |
| Frequency | 50/60Hz±3Hz (Auto sensing) | |
| Phase | Single-phase | |
| Power Factor | ≥0.99@220-230VAC | |
| Output | Rated Voltage | 220VAC |
| Frequency Range (Synchronous Range) | Follows mains when input is 47-53Hz (50Hz default) or 57-63Hz (60Hz default) | |
| Frequency Range (Battery Mode) | 50Hz±0.25Hz or 60Hz±0.3Hz | |
| Transfer Time | 4ms (standard conditions) | |
| Waveform (Battery Mode) | Pure Sine Wave | |
| THD | <3% (linear load), <6% (non-linear load) | |
| Current Crest Ratio | 3:1 | |
| Overload Protection | 100%-110%: audible alarm; 110%-130%: auto-shutdown after 30s or switch to bypass mode (normal input); >130%: immediate shutdown or switch to bypass mode (normal input) | |
| Battery | Built-in Battery Model | 12V/7-9AH |
| Number of Batteries | 6/8 | |
| Charging Time | 4 hours recover to 90% (built-in battery) | |
| Charging Current | Maximum 1A (built-in battery); 1A/2A/4A/6A adjustable (external battery) | |
| Charging Voltage | 82.1V±1%/109.4V±1% | |
| Environmental | Operating Temperature | 0~40℃ |
| Humidity | 20-95%RH (non-condensing) | |
| Noise | <45dBA@1m | |
| Management | Communication Interface | Optional intelligent RS-232 or USB, supporting Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC |
| Optional SNMP | Supports power management via SNMP manager and web browser | |
| Dimension (D×W×H) | 315×190×320 mm | |
| Net Weight | 13.5kg / 24.5 kg | |
FAQs
UPS stands for Uninterruptible Power Supply and is a device that provides a continuous supply of power to protect critical loads from power failures or fluctuations.
The main role of a UPS is to provide a backup power source to ensure that critical equipment can continue to operate when utility power is interrupted or unstable, avoiding data loss or equipment damage.
UPS is mainly divided into three types: offline, online and online interactive.
When choosing the power capacity of the UPS, you need to consider the total power demand of the load, it is usually recommended to choose a slightly larger than the total load power of the UPS to ensure sufficient standby time.
The standby time of a UPS depends on the battery capacity and load power. Standby time usually ranges from 10 minutes to several hours, and the specific needs can be determined according to the actual application scenario.