PRODUCT PARAMETERS
- True Online Double-Conversion Technology
- Advanced High-Frequency Transformerless Design
- Ultra-Wide Input Voltage & Frequency Range
- High Efficiency & Energy Savings
- Full Digital DSP Control
Description
Product Overview
The BK-L33 Series is a premium High-frequency online UPS featuring a transformer-less, high-frequency design—redefining reliability and efficiency as a top-tier Online double-conversion UPS. By eliminating bulky line-frequency transformers, this Transformerless online UPS cuts weight by up to 40%, slashes power losses, and lowers total cost of ownership (TCO) for global enterprises.
As a true High-frequency double-conversion UPS, it adopts online double-conversion technology, ensuring 24/7 inverter-powered load supply with 0ms transfer time. This seamless protection shields critical equipment from voltage sags, surges, and full blackouts—essential for mission-critical IT and industrial applications across overseas markets. Equipped with an intelligent active-PFC rectifier, the Double-conversion UPS boasts an ultra-wide input voltage range, maintains input power factor ≥0.99, and keeps THDi <5%, easing strain on upstream infrastructure and meeting global green-energy norms.
Fusing DSP-controlled SPWM precision, compact footprint, and enterprise-grade reliability, this UPS System sets a new standard for green, efficient power protection—ideal as a UPS for data center, UPS for server room, UPS for medical equipment, and UPS system for enterprise in North America, Europe, Southeast Asia, and beyond.
Applications
Finance
Ensures uninterrupted power for ATMs, trading terminals, and core banking systems. As a trusted UPS System for enterprise, it safeguards transaction integrity and data security during outages—critical for global financial institutions.
Telecommunications
Provides reliable backup for base stations, switching centers, and fiber network equipment. This Double-conversion UPS maintains 24/7 connectivity, preventing service disruption for telecom operators worldwide.
Government
Supports mission-critical operations in command centers, e-governance platforms, and secure facilities. The High-frequency online UPS delivers high-availability power protection for sensitive government infrastructure.
Transportation
Powers traffic control systems, railway signaling, and airport navigation. The Online double-conversion UPS ensures zero downtime for intelligent transport infrastructure across international markets.
Manufacturing
Protects PLCs, industrial PCs, and automated production lines from voltage fluctuations. This UPS System avoids costly downtime and equipment damage for global manufacturing plants.
Education
Secures campus networks, computer labs, and smart classroom systems. The High-frequency double-conversion UPS ensures continuity of digital learning for overseas universities and schools.
Data Centers & Server Rooms
Delivers clean, stable power to servers, storage, and networking gear. As a dedicated UPS for data center and UPS for server room, it meets Tier III/IV reliability standards with high efficiency and scalability—perfect for hyperscale and colocation facilities.
Precision Equipment Rooms
Supplies ultra-stable, low-distortion power to medical imaging devices, lab instruments, and semiconductor testing equipment. This UPS for medical equipment meets strict electrical quality requirements for healthcare and research institutions globally.
Product Features
Advanced Transformerless High-Frequency Online UPS Architecture
Eliminates bulky power frequency transformers, reducing overall weight by ~40% while boosting power density. This Transformerless online UPS cuts energy consumption and cooling requirements—aligning with overseas enterprises’ sustainability goals.
True Online Double-Conversion UPS Operation
Whether mains power is normal or abnormal, the inverter continuously powers the load with 0ms switching time. This Double-conversion UPS ensures uninterrupted, stable operation for critical equipment in global mission-critical environments.
Built-in Intelligent Active PFC for High-Frequency UPS
Supports an ultra-wide input voltage range, easily handling voltage sags/dips. It actively improves input power factor to ≥0.99 and limits THDi <5%, meeting international green energy and power quality standards.
Emergency Power Off (EPO) for Enterprise UPS System
One-button safe shutdown during fires, floods, or maintenance—protecting personnel and equipment in compliance with global safety regulations for commercial and industrial facilities.
DSP Full-Digital Control for Double-Conversion UPS
A high-performance DSP achieves all-digital control of PFC, inverter, and charger, delivering sub-millisecond response and higher precision. This enhances the reliability of the UPS System for sensitive overseas applications.
High Output Power Factor for Versatile Loads
Supports modern high-power IT, medical, and industrial loads without derating. This flexibility makes it a top choice as a UPS for data center, UPS for medical equipment, and UPS system for enterprise with diverse load requirements.
Specifications
| Model | BK-H11-15KVA | |
| Capacity | 15KVA/12KW | |
| Input | Wiring | Three-phase four wires + Ground |
| Rated Voltage | 380/400/415Vac | |
| Voltage Range | 208-304Vac (50% load); 304-478Vac (100% load) | |
| Frequency Range | 46Hz-54Hz (@50Hz system); 56Hz-64Hz (@60Hz system) | |
| Input Power Factor | ≥0.99 (100% load) | |
| Output | Wiring | Three-phase four wires + Ground |
| Rated Voltage | 380/400/415Vac | |
| Voltage Regulation | ±1% | |
| Frequency Range (Synchronous Range) | 46Hz-54Hz (@50Hz system); 56Hz-64Hz (@60Hz system) | |
| Frequency Range (Battery Mode) | 50Hz±0.1Hz or 60Hz±0.1Hz | |
| Output Power Factor | 0.8 | |
| Distortion (THDV%) | ≤2% (@100% linear load); ≤5% (@100% non-linear load) | |
| Overload Capability (AC Mode) | 100%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 1 second | |
| Overload Capability (Battery Mode) | 100%-110%: 30 seconds; 110%-130%: 10 seconds; >130%: 1 second | |
| Current Peak Ratio | 3:1 (maximum) | |
| Switching Time | 0ms | |
| Battery | Battery Type | External battery |
| Model | 12V | |
| Number of Batteries | 16/18/20 units (optional) | |
| Charging Current | 4A | |
| Charging Voltage | N×13.65VDC±1% (N=number of batteries) | |
| Efficiency | Line Mode | 89% |
| ECO Mode | 88% | |
| Management | Display Panel | LCD display / LED status indicator |
| Communication Function | Intelligent RS-232 or USB, supporting Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, MAC | |
| Optional SNMP | Supports power management via SNMP manager and web browser | |
| Environmental | Operating Temperature | 0~40℃ (Battery life will be reduced when temperature >25℃) |
| Humidity | <95% RH (non-condensing) | |
| Altitude | <1000m for Nominal power | |
| Noise Level | <60dB@1meter | |
| Standards | Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 Category C3 | |
| Physical | IP Class | IP20 |
| Dimensions (D×W×H) | 575×250×550 mm | |
| Weight | 37.8 kg | |
FAQs
UPS stands for Uninterruptible Power Supply and is a device that provides a continuous supply of power to protect critical loads from power failures or fluctuations.
The main role of a UPS is to provide a backup power source to ensure that critical equipment can continue to operate when utility power is interrupted or unstable, avoiding data loss or equipment damage.
UPS is mainly divided into three types: offline, online and online interactive.
When choosing the power capacity of the UPS, you need to consider the total power demand of the load, it is usually recommended to choose a slightly larger than the total load power of the UPS to ensure sufficient standby time.
The standby time of a UPS depends on the battery capacity and load power. Standby time usually ranges from 10 minutes to several hours, and the specific needs can be determined according to the actual application scenario.
.png)
.png)

-sub-1.jpg)
-sub-2.jpg)
-sub-3.png)
-sub-3.jpg)
-sub-4.jpg)
-sub-5.jpg)

-sub-1-150x150.jpg)
-sub-2-150x150.jpg)
-sub-3-150x150.png)
-sub-3-150x150.jpg)
-sub-4-150x150.jpg)
-sub-5-150x150.jpg)