BK-G33-800KVA-Industrial Power Frequency UPS
PRODUCT PARAMETERS
- Advanced Design
- High Power Factor
- Strong Environmental Adaptability
- Strong Overload Capacity
- N+X Parallel Redundancy Design
- Comprehensive Protection
- Advanced Battery Management
- Flexible Power Supply Modes
- Rich Optional Accessories
- Flexible Network Monitoring
Description
Product Overview
The BK-G33 Series power frequency UPS is a medium-to-large power, three-input/three-output, power frequency double-conversion online intelligent fully digital UPS.
It integrates digitization and networking, featuring a robust information acquisition system, signal processing system, and comprehensive protection system.
As a sine wave online high-intelligence uninterruptible power supply, the BK-G33 Series ensures continuous operation of your critical equipment during power instabilities or outages
Notes:Industrial Power Frequency UPS is also as known as Uninterruptible Power System, Uninterruptible Power Supply, Transformer Based UPS, Online Low Frequency Uninterruptible UPS.
Application
The BK-G33 Series is widely used in the following sectors:
- Micro data centers of small and medium-sized enterprises
- Branches of large enterprises
- Bank branches
- Storage, network equipment, VoIP, and communication devices
- Automation equipment and office terminals
- Precision instruments and equipment
Product Features
- Advanced Design
Online double-conversion design with zero phase-shift output isolation transformer ensures pure and stable power output.
- High Power Factor
Output power factor reaches 0.8, and input power factor up to 0.95 (with input filter), enhancing power efficiency.
- Strong Environmental Adaptability
Wide input voltage and frequency range adapts to harsh grid environments, ensuring stable operation.
- Strong Overload Capacity
Excellent output overload and short-circuit resistance (sustainable for 5 seconds) protects equipment from damage.
- N+X Parallel Redundancy Design
Supports up to 6 units in parallel, including different models, improving system reliability and scalability.
- Quasi-Modular Design
Independent heat sinks for power devices facilitate installation and on-site maintenance, reducing maintenance costs.
- LBS Synchronization
Enables synchronization of two independent UPS systems, enhancing overall system reliability.
- Generator Compatibility
Power Walk In slow start function reduces inrush current, protecting generators and UPS equipment.
- Advanced Battery Management
Includes temperature compensation, battery life extension, discharge time prediction, and battery self-test, extending battery life and ensuring performance.
- DSP Full Digital Control
Dual DSP digital control technology ensures system stability and reliability, improving control accuracy and response speed.
- Automatic Power-On
Memory auto-start function enhances equipment usability.
- Large LCD Display
Chinese/English LCD menu and real-time data display for easy monitoring of equipment status.
- Flexible Network Monitoring
Standard RS232/RS485 communication interfaces, optional SNMP/JBUS/MODBUS dry contact cards for remote monitoring and management.
- Intelligent Fan Speed Control
Adjusts fan speed based on internal temperature and load, reducing noise and energy consumption.
- DC Start Function
Batteries can be used directly to start the UPS, convenient for use without mains power.
- Comprehensive Protection
Includes power-on self-diagnosis, short-circuit, inverter over-temperature, battery under-voltage, battery over-charge, and surge protection.
- Flexible Power Supply Modes
Offers normal mode, combined power supply mode, ECO mode, auto-start mode, and variable frequency mode to meet diverse business needs.
- Rich Optional Accessories
Includes harmonic filters, bypass current sharing inductors, Class C lightning protection boxes, parallel cables, load synchronization (LBS) cables, SNMP/JBUS/MODBUS/dry contact cards, battery ground fault components, battery temperature sensors, and UPS room signals.
Technical Advantages
- Stable and Reliable Power Protection
Effectively solves power problems such as outages, voltage fluctuations, and frequency variations, ensuring continuous operation of critical equipment.
- Highly Integrated Digital and Networking Technologies
Facilitates management and monitoring, improving efficiency and reducing operational costs.
- Strong Environmental Adaptability and Overload Capacity
Ensures stable operation under extreme conditions, enhancing equipment availability.
- Flexible Parallel Redundancy Design and Multiple Power Supply Modes
Meets diverse business needs, improving system reliability and scalability.
Optional Accessories
- Parallel Cable
- Load Synchronization (LBS) Cable
- SNMP/JBUS/MODBUS/Dry Contact Card
Specifications
| Model | BK-G33-800KVA | |||
| Capacity | KVA/KW | 800KVA/720KW (12 pulses) | ||
| Number of parallel machines | Support up to 8 units | |||
| Efficiency | Double conversion mode | ≥90% | ||
| Economy mode | ≥96% | |||
| Input | Main Input | Rated Voltage | 380/400/415Vac | |
| Voltage Tolerance | ±25% | |||
| Wiring | 3 phase 5wires(3L+N+PE) / 3 phase 4 wires(3L+PE) | |||
| Frequency Tolerance | 45~65Hz | |||
| Power Factor | >0.95(Add filter) | |||
| Rated AC input | 380/400/415Vac | |||
| Bypass Input | Nominal Voltage | 380/400/415Vac | ||
| Rated AC input | 380/400/415Vac | |||
| Voltage Tolerance | ±25% | |||
| Wiring | 3 phase 5wires(3L+N+PE) / 3 phase 4 wires(3L+PE) | |||
| Frequency Tolerance | ±2%(±0. 5%, +1%, ±2%, ±3% Configurable) | |||
| Output | Nominal Voltage | 380/400/415 ±1% | ||
| Power Factor | ≥0.8(Customizable) | |||
| Frequency Tolerance | Automatically track bypass frequency | |||
| Output THD | Sine wave THDV is less than 1% (pure linear load) | |||
| Switching time | 0 | |||
| Efficiency | ≥95% | |||
| Output voltage regulation accuracy | Steady State | ±1% | ||
| Transient | ±5% | |||
| Overload Capacity | 105%~110%:60min Switch to bypass; 110%~125%:10min Switch to bypass; >125%: 10s Switch to bypass | |||
| Other parameters | Battery | Battery voltage range | 384(Standard) / 396/408(Customizable) | |
| Environmental | Operating Temperature | -10~40℃ | ||
| Storage Temperature | -25~55℃(Battery not included) | |||
| Humidity | 0~95% (Non-condensing) | |||
| Altitude | 1500m, If the limit is exceeded, use the derated capacity in accordance with GB/T3859.2. | |||
| Noise Level | <70dB@ 1 meters | |||
| Alarm function | Alarm range | Output overload, AC power abnormality, UPS failure, battery undervoltage | ||
| Alarm method | Sound alarm | |||
| Protection function | Output short circuit, overload, over temperature, battery undervoltage, output over-voltage and under-voltage, lightning protection (optional) | |||
| Communications and Management | Communication function | Standard configuration:RS232 Optional configuration:RS485/SNMP/Dry Contact | ||
| Display Panel | LCD display / LED status indicator | |||
| Standard | Electrical performance standards | YD/T1095-2017 | ||
| Production Compliance | IEC 60529 ,IEC 60664 , IEC 60755 | |||
| EMC/LVD | EC62040-2,IEC62040-3 | |||
| Certificate | CE ROHS | |||
| Dimensions (W×D×H) | 2000*870*2050mm | |||
| Weight | 1820kg | |||
| Optional accessories | SNMP | Support SNMP management and network management | ||
FAQs
UPS stands for Uninterruptible Power Supply and is a device that provides a continuous supply of power to protect critical loads from power failures or fluctuations.
The main role of a UPS is to provide a backup power source to ensure that critical equipment can continue to operate when utility power is interrupted or unstable, avoiding data loss or equipment damage.
UPS is mainly divided into three types: offline, online and online interactive.
When choosing the power capacity of the UPS, you need to consider the total power demand of the load, it is usually recommended to choose a slightly larger than the total load power of the UPS to ensure sufficient standby time.
The standby time of a UPS depends on the battery capacity and load power. Standby time usually ranges from 10 minutes to several hours, and the specific needs can be determined according to the actual application scenario.